CallRequest a quote

Testing and measurement laboratory · ATS 01-008

Accredited testing, energy efficiency and engineering.

The accredited laboratory is our core business. We also issue energy passports and, as since 1990, design and install HVAC systems. Each service has its own page with methods, standards and FAQs.

01 / 09 ATS 01-008

Accredited laboratory

On-site testing for buildings, HVAC systems and noise control. We have been accredited by the Accreditation Body of Serbia since 2001, test to the standards in our scope of accreditation and deliver the results in a formal test report.

  • Noise measurement
  • Sound insulation and acoustics
  • Air permeability (blower door)
  • Ventilation and air conditioning
  • Thermography and heat transmission

Learn more

CALIBRATEDΔp 245 Paq 4 860 m³/hTEST REPORTATS01-008CalibratedinstrumentsAPitot tubein the ductBDigitalmanometerCDataprocessingDReportATS 01-008E
  • ACalibrated instruments
  • BPitot tube in the duct
  • CDigital manometer
  • DData processing
  • EReport with ATS 01-008
  1. 1Calibrated equipment and test plan
  2. 2On-site measurement to the standard method
  3. 3Processing and evaluation of results
  4. 4Test report from the accredited laboratory
Values shown are illustrative.

02 / 09

Energy passport & efficiency

We issue energy passports and prepare energy efficiency reports for new and existing buildings. With licensed energy efficiency engineers and our own accredited laboratory, the calculation can be backed by on-site measurements.

  • Energy passport
  • Energy efficiency report
  • Energy survey
  • Improvement plan
  • Envelope measurements

Learn more

12.40 mQ H,nd68 kWh/m²aA+ABCDEFGBEnergysurveyAHeatlossesBEnergy calculationCEnergy classD
  • ABuilding energy survey
  • BHeat losses through the envelope
  • CQ H,nd calculation
  • DEnergy class
  1. 1Energy survey of the building
  2. 2Analysis of envelope heat losses
  3. 3Calculating annual heating demand
  4. 4Energy class A+ to G and the passport
Values shown are illustrative.

03 / 09

Noise measurement

Accredited noise measurement in Belgrade and across Serbia: environmental noise, noise in apartments and residential buildings, noise from venues, HVAC units and industry, and workplace noise. We measure to ISO 1996-1 and 1996-2:2019 and issue a noise measurement report as an authorized organization.

  • Environmental noise
  • Apartments and residential buildings
  • Venues, industry, traffic
  • Workplace noise
  • Sound power of sources

Learn more

CAFÉREFERENCE POINTLAeqDEN52.4 dB(A)Lp, dB(A)limitNOISE TEST REPORTATS01-008Noise sourceASound levelmeterBLAeq day /evening / nightCLeveltime historyDReportE
  • ANoise source (HVAC unit, venue)
  • BSound level meter at the reference point
  • CEquivalent level LAeq per period
  • DLevel time history and limit
  • ETest report
  1. 1Noise source and reference measuring point
  2. 2LAeq measured for day, evening and night
  3. 3Analysis against the limit values
  4. 4Noise measurement report
Values shown are illustrative.

04 / 09 ATS 01-008

Sound insulation & building acoustics

We test sound insulation of buildings on site: walls and floors between apartments, impact sound, façades and windows, plus reverberation time and sound power of sources, all within ATS accreditation 01-008. For environmental noise see Noise measurement.

  • Noise measurement
  • Workplace noise and noise sources
  • Sound insulation between rooms
  • Impact sound
  • Façades

Learn more

SOURCE ROOMRECEIVING ROOM46 dBR′w54 dBSoundsourceASeparating wallBSound levelmeterCVibrationDInsulationratingE
  • ASound source (dodecahedron)
  • BSeparating wall
  • CSound level meter
  • DStructural vibration
  • ESound insulation rating
  1. 1Sound source in the source room
  2. 2Sound passes through the separating element
  3. 3Level measured in the receiving room
  4. 4Sound insulation rated to the standard
Values shown are illustrative.

05 / 09 ATS 01-008

Blower door test

We measure how airtight the building envelope is: a fan in the doorway creates a pressure difference and we measure how much air passes through window joints, service penetrations and cracks. The test is within our ATS scope of accreditation.

  • Building air permeability
  • Apartments and test zones
  • Leak locations
  • Testing before finishes

Learn more

Δp 50 Pa−50 Pan501.4 h⁻¹Blower doorfanAManometerBAirleaksCn50 resultD
  • ABlower door fan
  • BDigital manometer
  • CAir leak locations
  • Dn50 result
  1. 1Fan and membrane fitted in the doorway
  2. 2Pressure difference up to 50 Pa
  3. 3Air enters through joints and cracks
  4. 4n50 result and leak locations
Values shown are illustrative.

06 / 09 ATS 01-008

HVAC and ventilation testing

We check that ventilation and air-conditioning systems deliver their design airflows and that ductwork is airtight. Airflow, duct leakage and heat exchanger tests are in our accredited scope, and the same team handles balancing.

  • Airflow – Pitot traverse
  • Flow through orifices and Venturi tubes
  • Duct leakage
  • Heat exchanger performance
  • Balancing and regulation

Learn more

SECTION A-Av 8.4 m/s400 PaAirflowDuct airtightness4 860 m³/hclass CAir handlingunitATestportsBVelocityfieldCLeakagetest rigDResultE
  • AAir handling unit
  • BTest ports on the duct
  • CVelocity field in the section
  • DLeakage test rig
  • ETest result
  1. 1Test ports and measuring grid in the cross-section
  2. 2Pitot traverse: velocity field and airflow
  3. 3Leakage test: the duct under pressure
  4. 4Airflow and airtightness class in the report
Values shown are illustrative.

07 / 09 ATS 01-008

Microclimate & working environment

We measure microclimate in offices, production halls, hospitals and schools and assess thermal comfort. Physical testing of the working environment is in our ATS 01-008 scope.

  • Air temperature and humidity
  • Air speed
  • Mean radiant temperature
  • PMV and PPD

Learn more

1.1 m0.6 m0.1 mt 23.4 °Cφ 45 %v 0.12 m/str 24.1 °C−3−2−10+1+2+3PMV / PPDPPD 7 %PMV +0.3GlobethermometerAAnemometerBTemperature,humidity, speedCPMV / PPDindicesD
  • AGlobe thermometer (mean radiant temperature)
  • BAnemometer (air speed)
  • CMicroclimate readings
  • DPMV / PPD comfort indices
  1. 1Sensor stand at 0.1 / 0.6 / 1.1 m
  2. 2Air temperature, humidity, air speed and radiation
  3. 3Calculating the PMV and PPD comfort indices
  4. 4Working-environment assessment in the report
Values shown are illustrative.

08 / 09 ATS 01-008

Thermography & insulation testing

A thermal camera shows where a building loses heat, and in-situ heat-flow measurement tells how well a wall or roof insulates. Both methods are in our accredited scope.

  • Building thermography
  • Plant and installation thermography
  • Heat transmission and thermal resistance
  • Moisture and condensation
  • Air permeability

Learn more

9.6 °CU 0.38 W/m²K20°-5°ThermalcameraAThermalbridgeBU-valuemeasurementCReportD
  • AThermal camera
  • BThermal bridge at the ring beam
  • CHeat-flux sensor (U-value)
  • DReport with thermograms
  1. 1Thermal camera and test conditions
  2. 2The thermogram reveals temperature patterns
  3. 3Thermal bridges and heat-flow (U-value) measurement
  4. 4Report with thermograms and recommendations
Values shown are illustrative.

09 / 09

Engineering & installation

Engineering is what the company has been known for since 1990: from survey and design to installation, commissioning and final measurements with a report. Today we do it alongside our own accredited laboratory.

  • Boiler rooms
  • Compressed air
  • Central and warm-air heating
  • Air conditioning
  • Process parameters

Learn more

INSTAL-01 / SCHEMEDesignAAir handlingunitBBoiler roomCTests andhandoverD
  • ADesign documents
  • BAir handling unit
  • CBoiler room
  • DFinal measurements
  1. 1Survey and design
  2. 2Installing equipment and pipework
  3. 3Commissioning and balancing
  4. 4Final measurements and report
Values shown are illustrative.

Contact

Tell us what needs testing.

Send the building type, location and the test you need, and we will reply with a quote and a date.