Accredited laboratory · ATS 01-008
Accredited testing for buildings and building services.
Noise and sound insulation, blower door, airflow, thermography and microclimate. A testing and measurement laboratory accredited to ISO/IEC 17025:2017, with reports that stand up at handover and inspection.
Most requested: Noise measurementEnergy passportBlower door test
- ACalibrated instruments
- BPitot tube in the duct
- CDigital manometer
- DData processing
- EReport with ATS 01-008
01 / Laboratory
We measure what others estimate: sound, air, heat and energy in buildings, accredited since 2001.
02 / Services
What we test
and what we do.
Accredited laboratory
ATS accreditation 01-008 to ISO/IEC 17025:2017: noise and sound insulation, air permeability, airflow, thermography and microclimate, all on site.
Energy passport & efficiency
Energy passport for an apartment, house or commercial building: survey, calculation, energy class A+ to G and recommended measures.
Noise measurement
Environmental, residential and workplace noise measurement to ISO 1996. ATS accreditation 01-008 and Ministry authorization.
Sound insulation & building acoustics
Airborne sound insulation of walls, floors and façades (EN ISO 16283), impact sound, reverberation and sound power.
Blower door test
Blower door test to EN ISO 9972: n50 and air leak locations for houses, apartments and buildings.
HVAC and ventilation testing
Airflow by Pitot tube and orifice, duct leakage tests (EN 12237, EN 1507) and heat exchangers.
Microclimate & working environment
Temperature, humidity, air speed, radiant temperature and PMV/PPD for working environments.
Thermography & insulation testing
Thermography to EN ISO 6781-1 and in-situ U-value (ISO 9869-1). Thermal bridges and leaks.
Engineering & installation
HVAC design and installation since 1990: boiler rooms, heating, air conditioning and compressed air.
03 / How we test
Every test,
step by step.
Accredited laboratory
On-site testing for buildings, HVAC systems and noise control. We have been accredited by the Accreditation Body of Serbia since 2001, test to the standards in our scope of accreditation and deliver the results in a formal test report.
Learn more- ACalibrated instruments
- BPitot tube in the duct
- CDigital manometer
- DData processing
- EReport with ATS 01-008
- 1Calibrated equipment and test plan
- 2On-site measurement to the standard method
- 3Processing and evaluation of results
- 4Test report from the accredited laboratory
Blower door test
We measure how airtight the building envelope is: a fan in the doorway creates a pressure difference and we measure how much air passes through window joints, service penetrations and cracks. The test is within our ATS scope of accreditation.
Learn more- ABlower door fan
- BDigital manometer
- CAir leak locations
- Dn50 result
- 1Fan and membrane fitted in the doorway
- 2Pressure difference up to 50 Pa
- 3Air enters through joints and cracks
- 4n50 result and leak locations
Energy passport & efficiency
We issue energy passports and prepare energy efficiency reports for new and existing buildings. With licensed energy efficiency engineers and our own accredited laboratory, the calculation can be backed by on-site measurements.
Learn more- ABuilding energy survey
- BHeat losses through the envelope
- CQ H,nd calculation
- DEnergy class
- 1Energy survey of the building
- 2Analysis of envelope heat losses
- 3Calculating annual heating demand
- 4Energy class A+ to G and the passport
Sound insulation & building acoustics
We test sound insulation of buildings on site: walls and floors between apartments, impact sound, façades and windows, plus reverberation time and sound power of sources, all within ATS accreditation 01-008. For environmental noise see Noise measurement.
Learn more- ASound source (dodecahedron)
- BSeparating wall
- CSound level meter
- DStructural vibration
- ESound insulation rating
- 1Sound source in the source room
- 2Sound passes through the separating element
- 3Level measured in the receiving room
- 4Sound insulation rated to the standard
Thermography & insulation testing
A thermal camera shows where a building loses heat, and in-situ heat-flow measurement tells how well a wall or roof insulates. Both methods are in our accredited scope.
Learn more- AThermal camera
- BThermal bridge at the ring beam
- CHeat-flux sensor (U-value)
- DReport with thermograms
- 1Thermal camera and test conditions
- 2The thermogram reveals temperature patterns
- 3Thermal bridges and heat-flow (U-value) measurement
- 4Report with thermograms and recommendations
04 / Scope of accreditation
Accredited methods, not promises.
Every test in our scope follows a named standard within a defined range. The scope is public and can be checked in the Accreditation Body of Serbia register.
- Accreditation No.
- ATS 01-008
- Standard
- ISO/IEC 17025:2017
- Initial accreditation
- 3 Sep 2001
- Valid until
- 15 Mar 2027
- Building air permeabilityEN ISO 9972
- Airflow – Pitot traverseISO 3966
- Duct leakageEN 12237 · EN 1507
- ThermographyEN ISO 6781-1
- Heat transmissionISO 9869-1
- PMV / PPDEN ISO 7730
- Environmental noiseISO 1996-1/-2
- Sound insulationEN ISO 16283-1/-2/-3
- Sound powerEN ISO 3744 · 3746
- ReverberationEN ISO 3382-2
05 / Process
From enquiry to
accredited report.
- 01
Enquiry
Tell us about the building and the test.
- 02
Test plan
Methods, test points and date.
- 03
On-site testing
Calibrated equipment, standard method.
- 04
Evaluation
Against design, standard or regulation.
- 05
Test report
Accredited report for handover, supervision or inspection.
- 06
Recommendations
What to fix if a result fails.
06 / Energy efficiency
Energy passports, backed by measurement.
We are authorized to issue energy passports and prepare energy efficiency reports. When the calculation needs confirmation, our accredited lab provides thermography, U-value and blower door tests.
Energy passportEnergy class
07 / Accreditation and licences
Accredited. Authorized.
Licensed.
ATS 01-008
Accredited testing and measurement laboratory, ISO/IEC 17025:2017Ministry authorization
Environmental noise measurement, decision of 20 Oct 2025SRPS ISO 9001
Certified quality management systemEnergy passport
Authorized to issue energy passportsIKS licences
Energy efficiency, design and constructionFAQ
FAQ
What does the accredited laboratory do?
It carries out on-site tests to the standards in ATS scope 01-008: noise and sound insulation, air permeability, airflow and duct leakage, thermography, heat transmission and microclimate. The result is a formal test report.
Do you issue energy passports?
Yes. We are authorized to issue energy passports and employ licensed energy efficiency engineers.
Do you still do engineering?
Yes. We have designed and installed HVAC systems since 1990, with final tests by our laboratory.
Where do you work?
We are based in New Belgrade and test on site; locations outside Belgrade by arrangement.
Contact
Tell us what needs testing.
Send the building type, location and the test you need, and we will reply with a quote and a date.