CallRequest a quote

Accredited laboratory · ATS 01-008

Accredited testing for buildings and building services.

Noise and sound insulation, blower door, airflow, thermography and microclimate. A testing and measurement laboratory accredited to ISO/IEC 17025:2017, with reports that stand up at handover and inspection.

Most requested: Noise measurementEnergy passportBlower door test

  • ATS 01-008Accreditation
  • ISO/IEC 17025Standard
  • 2001.First accredited
CALIBRATEDΔp 245 Paq 4 860 m³/hTEST REPORTATS01-008CalibratedinstrumentsAPitot tubein the ductBDigitalmanometerCDataprocessingDReportATS 01-008E
  • ACalibrated instruments
  • BPitot tube in the duct
  • CDigital manometer
  • DData processing
  • EReport with ATS 01-008
Values shown are illustrative.
Hotel Hyatt RegencyKlinički centar SrbijeTE Nikola TeslaTelekom SrbijaGrađevinska direkcija SrbijeGrad Beograd – Gradska upravaEnergoprojekt VisokogradnjaAgencija za kontrolu letenjaEPS – Elektrodistribucija BeogradNBS – Kovnica novca TopčiderHotel MetropolPoslovni prostori

01 / Laboratory

We measure what others estimate: sound, air, heat and energy in buildings, accredited since 2001.

01-008ATS accreditation No.
2001first accredited
17025SRPS ISO/IEC 17025:2017
1990company founded

03 / How we test

Every test,
step by step.

Accredited laboratory

On-site testing for buildings, HVAC systems and noise control. We have been accredited by the Accreditation Body of Serbia since 2001, test to the standards in our scope of accreditation and deliver the results in a formal test report.

Learn more
CALIBRATEDΔp 245 Paq 4 860 m³/hTEST REPORTATS01-008CalibratedinstrumentsAPitot tubein the ductBDigitalmanometerCDataprocessingDReportATS 01-008E
  • ACalibrated instruments
  • BPitot tube in the duct
  • CDigital manometer
  • DData processing
  • EReport with ATS 01-008
  1. 1Calibrated equipment and test plan
  2. 2On-site measurement to the standard method
  3. 3Processing and evaluation of results
  4. 4Test report from the accredited laboratory
Values shown are illustrative.

04 / Scope of accreditation

Accredited methods, not promises.

Every test in our scope follows a named standard within a defined range. The scope is public and can be checked in the Accreditation Body of Serbia register.

Accreditation No.
ATS 01-008
Standard
ISO/IEC 17025:2017
Initial accreditation
3 Sep 2001
Valid until
15 Mar 2027

Full scope

  • Building air permeabilityEN ISO 9972
  • Airflow – Pitot traverseISO 3966
  • Duct leakageEN 12237 · EN 1507
  • ThermographyEN ISO 6781-1
  • Heat transmissionISO 9869-1
  • PMV / PPDEN ISO 7730
  • Environmental noiseISO 1996-1/-2
  • Sound insulationEN ISO 16283-1/-2/-3
  • Sound powerEN ISO 3744 · 3746
  • ReverberationEN ISO 3382-2

05 / Process

From enquiry to
accredited report.

  1. Enquiry

    Tell us about the building and the test.

  2. Test plan

    Methods, test points and date.

  3. On-site testing

    Calibrated equipment, standard method.

  4. Evaluation

    Against design, standard or regulation.

  5. Test report

    Accredited report for handover, supervision or inspection.

  6. Recommendations

    What to fix if a result fails.

06 / Energy efficiency

Energy passports, backed by measurement.

We are authorized to issue energy passports and prepare energy efficiency reports. When the calculation needs confirmation, our accredited lab provides thermography, U-value and blower door tests.

Energy passport

Energy class

07 / Accreditation and licences

Accredited. Authorized.
Licensed.

ATS 01-008

Accredited testing and measurement laboratory, ISO/IEC 17025:2017

Ministry authorization

Environmental noise measurement, decision of 20 Oct 2025

SRPS ISO 9001

Certified quality management system

Energy passport

Authorized to issue energy passports

IKS licences

Energy efficiency, design and construction

FAQ

FAQ

What does the accredited laboratory do?

It carries out on-site tests to the standards in ATS scope 01-008: noise and sound insulation, air permeability, airflow and duct leakage, thermography, heat transmission and microclimate. The result is a formal test report.

Do you issue energy passports?

Yes. We are authorized to issue energy passports and employ licensed energy efficiency engineers.

Do you still do engineering?

Yes. We have designed and installed HVAC systems since 1990, with final tests by our laboratory.

Where do you work?

We are based in New Belgrade and test on site; locations outside Belgrade by arrangement.

Contact

Tell us what needs testing.

Send the building type, location and the test you need, and we will reply with a quote and a date.