EN ISO 7730 · accredited
Microclimate and the working environment.
We measure microclimate in offices, production halls, hospitals and schools and assess thermal comfort. Physical testing of the working environment is in our ATS 01-008 scope.
- ATS 01-008accredited lab
- ISO/IEC 17025:2017
- since 2001accredited
- AGlobe thermometer (mean radiant temperature)
- BAnemometer (air speed)
- CMicroclimate readings
- DPMV / PPD comfort indices
- 1Sensor stand at 0.1 / 0.6 / 1.1 m
- 2Air temperature, humidity, air speed and radiation
- 3Calculating the PMV and PPD comfort indices
- 4Working-environment assessment in the report
What we measure
Microclimate & working environment
Air temperature and humidity
Temperature −50 to 125 °C and relative humidity 0 to 100 %.
Air speed
0 to 5 m/s, relevant for draughts and ventilation.
Mean radiant temperature
The effect of warm and cold surfaces, measured with a globe thermometer.
PMV and PPD
Thermal comfort to EN ISO 7730:2008 and DIN EN 13779:2007.
Accreditation and standards
ATS 01-008 scope of accreditation
The tests on this page are covered by the scope of accreditation of our Testing and Measurement Laboratory. Reports carry the accreditation mark; methods and ranges are listed below.
- Accreditation No.
- ATS 01-008
- Standard
- ISO/IEC 17025:2017
- Initial accreditation
- 3 Sep 2001
- Valid until
- 15 Mar 2027
| Subject | Test | Range | Reference document |
|---|---|---|---|
| Working environment | Air temperature, humidity and air speed | −50–125 °C; 0–100 %; 0–5 m/s | Rulebook on preventive measures for safe and healthy work at the workplace (Off. Gazette RS 21/09, 1/19) |
| Mean radiant temperature | −50 °C to 200 °C | Ahlborn ALMEMO manufacturer manual | |
| PMV and PPD comfort indices | — | SRPS EN ISO 7730:2008; DIN EN 13779:2007 |
Process
How it works
- 01
Plan
Workstations and measuring period.
- 02
Sensor stand
Sensors at 0.1, 0.6 and 1.1 m.
- 03
Measurement
Temperature, humidity, air speed and radiation.
- 04
PMV and PPD
Comfort indices from activity and clothing data.
- 05
Assessment
Comparison with the regulation and standard.
- 06
Report
Test report with recommendations.
What you get
Report and results
- Working environment test report
- Microclimate values per position
- PMV and PPD indices
- Assessment against regulation and standard
- HVAC recommendations
Who needs it
Who we work for
- Employers and OHS services
- Production plants and warehouses
- Offices
- Hospitals and schools
- Facility managers after HVAC upgrades


FAQ
Frequently asked questions
What is workplace microclimate?
Air conditions at the workstation: temperature, humidity, air speed and radiant heat from surfaces.
What are PMV and PPD?
PMV is the predicted mean thermal sensation from −3 (cold) to +3 (hot); PPD is the predicted percentage of dissatisfied people. Both follow EN ISO 7730.
Is it accredited?
Yes. Temperature, humidity, air speed, mean radiant temperature and PMV/PPD are in our scope.
Contact
Tell us what needs testing.
Send the building type, location and the test you need, and we will reply with a quote and a date.