CallRequest a quote

EN ISO 7730 · accredited

Microclimate and the working environment.

We measure microclimate in offices, production halls, hospitals and schools and assess thermal comfort. Physical testing of the working environment is in our ATS 01-008 scope.

  • ATS 01-008accredited lab
  • ISO/IEC 17025:2017
  • since 2001accredited
1.1 m0.6 m0.1 mt 23.4 °Cφ 45 %v 0.12 m/str 24.1 °C−3−2−10+1+2+3PMV / PPDPPD 7 %PMV +0.3GlobethermometerAAnemometerBTemperature,humidity, speedCPMV / PPDindicesD
  • AGlobe thermometer (mean radiant temperature)
  • BAnemometer (air speed)
  • CMicroclimate readings
  • DPMV / PPD comfort indices
  1. 1Sensor stand at 0.1 / 0.6 / 1.1 m
  2. 2Air temperature, humidity, air speed and radiation
  3. 3Calculating the PMV and PPD comfort indices
  4. 4Working-environment assessment in the report
Values shown are illustrative.

What we measure

Microclimate & working environment

01

Air temperature and humidity

Temperature −50 to 125 °C and relative humidity 0 to 100 %.

02

Air speed

0 to 5 m/s, relevant for draughts and ventilation.

03

Mean radiant temperature

The effect of warm and cold surfaces, measured with a globe thermometer.

04

PMV and PPD

Thermal comfort to EN ISO 7730:2008 and DIN EN 13779:2007.

Accreditation and standards

ATS 01-008 scope of accreditation

The tests on this page are covered by the scope of accreditation of our Testing and Measurement Laboratory. Reports carry the accreditation mark; methods and ranges are listed below.

Accreditation No.
ATS 01-008
Standard
ISO/IEC 17025:2017
Initial accreditation
3 Sep 2001
Valid until
15 Mar 2027
SubjectTestRangeReference document
Working environmentAir temperature, humidity and air speed−50–125 °C; 0–100 %; 0–5 m/sRulebook on preventive measures for safe and healthy work at the workplace (Off. Gazette RS 21/09, 1/19)
Mean radiant temperature−50 °C to 200 °CAhlborn ALMEMO manufacturer manual
PMV and PPD comfort indices—SRPS EN ISO 7730:2008; DIN EN 13779:2007

Scope of accreditation (PDF)

Process

How it works

  1. Plan

    Workstations and measuring period.

  2. Sensor stand

    Sensors at 0.1, 0.6 and 1.1 m.

  3. Measurement

    Temperature, humidity, air speed and radiation.

  4. PMV and PPD

    Comfort indices from activity and clothing data.

  5. Assessment

    Comparison with the regulation and standard.

  6. Report

    Test report with recommendations.

What you get

Report and results

  • Working environment test report
  • Microclimate values per position
  • PMV and PPD indices
  • Assessment against regulation and standard
  • HVAC recommendations

Who needs it

Who we work for

  • Employers and OHS services
  • Production plants and warehouses
  • Offices
  • Hospitals and schools
  • Facility managers after HVAC upgrades
Humidity measurement
Humidity measurement
Air speed measurement
Air speed measurement

FAQ

Frequently asked questions

What is workplace microclimate?

Air conditions at the workstation: temperature, humidity, air speed and radiant heat from surfaces.

What are PMV and PPD?

PMV is the predicted mean thermal sensation from −3 (cold) to +3 (hot); PPD is the predicted percentage of dissatisfied people. Both follow EN ISO 7730.

Is it accredited?

Yes. Temperature, humidity, air speed, mean radiant temperature and PMV/PPD are in our scope.

Contact

Tell us what needs testing.

Send the building type, location and the test you need, and we will reply with a quote and a date.