CallRequest a quote

ATS 01-008 · ISO/IEC 17025:2017

Accredited testing and measurement laboratory.

On-site testing for buildings, HVAC systems and noise control. We have been accredited by the Accreditation Body of Serbia since 2001, test to the standards in our scope of accreditation and deliver the results in a formal test report.

  • ATS 01-008accredited lab
  • ISO/IEC 17025:2017
  • since 2001accredited
CALIBRATEDΔp 245 Paq 4 860 m³/hTEST REPORTATS01-008CalibratedinstrumentsAPitot tubein the ductBDigitalmanometerCDataprocessingDReportATS 01-008E
  • ACalibrated instruments
  • BPitot tube in the duct
  • CDigital manometer
  • DData processing
  • EReport with ATS 01-008
  1. 1Calibrated equipment and test plan
  2. 2On-site measurement to the standard method
  3. 3Processing and evaluation of results
  4. 4Test report from the accredited laboratory
Values shown are illustrative.

Accreditation and standards

ATS 01-008 scope of accreditation

The Instalacija Inženjering Testing and Measurement Laboratory is accredited by the Accreditation Body of Serbia to ISO/IEC 17025:2017. All tests are carried out on site. This is the complete detailed scope, valid from 28 July 2025.

Accreditation No.
ATS 01-008
Standard
ISO/IEC 17025:2017
Initial accreditation
3 Sep 2001
Valid until
15 Mar 2027
SubjectTestRangeReference document
Water and air distribution installations (air conditioning and ventilation)Flow measurement with orifice plates, nozzles and Venturi tubes0–200 kPaSRPS EN ISO 5167-1:2022; SRPS EN ISO 5167-2:2022
Flow measurement by the velocity-area method with static Pitot tubes0–3500 PaSRPS ISO 3966:2023
Air duct leakage testing750 Pa negative – 2000 Pa positive pressureSRPS EN 1507:2010; SRPS EN 12237:2010; DW/143:2000; DW/144:1998; EUROVENT 2/2:1996; SMACNA
Heat exchangersPerformance testing of heat exchangers0–200 kPa; −20 °C to 200 °CSRPS EN 305:2012; SRPS EN 306:2012
Apartments and buildingsAir permeability testing of apartments—SRPS U.J5.100:1984 (withdrawn)
Air permeability of buildings – fan pressurization method50–39 000 m³/hSRPS EN ISO 9972:2016
Building structuresHeat transmission; thermal resistance and thermal transmittance−25 °C to 20 °C; 0–150 W/m²SRPS U.J5.062:1984 (withdrawn); SRPS ISO 9869-1:2016
District heating, thermal power installations, electrical power plants, building thermal insulationThermographic testing−10 °C to 1500 °CSRPS EN ISO 6781-1:2023; FLIR manufacturer manual
Working environmentAir temperature, humidity and air speed−50–125 °C; 0–100 %; 0–5 m/sRulebook on preventive measures for safe and healthy work at the workplace (Off. Gazette RS 21/09, 1/19)
Mean radiant temperature−50 °C to 200 °CAhlborn ALMEMO manufacturer manual
PMV and PPD comfort indices—SRPS EN ISO 7730:2008; DIN EN 13779:2007
EnvironmentDetermination of noise levels20–130 dBSRPS ISO 1996-1:2019; SRPS ISO 1996-2:2019
Noise sourcesSound power level of noise sources20–130 dBSRPS EN ISO 3744:2011; SRPS EN ISO 3746:2011
Building materials, elements, structures, buildings and hallsField measurement of airborne sound insulation of façade elements and façades20–80 dBSRPS EN ISO 16283-3:2017; SRPS EN ISO 717-1:2021
Field measurement of airborne sound insulation between rooms20–80 dBSRPS EN ISO 16283-1:2016/A1:2018; SRPS EN ISO 717-1:2021
Field measurement of impact sound insulation of floors20–80 dBSRPS EN ISO 16283-2:2021; SRPS EN ISO 717-2:2021
Reverberation time measurement0.1–20 sSRPS U.J6.057:1982 (withdrawn); SRPS EN ISO 3382-2:2010

Scope of accreditation (PDF)

Process

How it works

  1. Enquiry and test plan

    We define methods, test points and timing from the design and use of the building.

  2. Calibrated equipment

    We arrive with instruments prepared for the method being applied.

  3. On-site testing

    Tests are carried out to the standard in our scope, with a field record.

  4. Processing and evaluation

    Results are compared with the design, the standard or the regulation.

  5. Test report

    You receive a report from an accredited laboratory, ready for handover, supervision or inspection.

  6. Recommendations

    If a result fails, we explain why and what needs fixing.

What you get

Report and results

  • Test report from an accredited laboratory (ATS 01-008)
  • Measured values with uncertainty where applicable
  • Comparison with the design, standard or legal requirement
  • Description of method, test points and equipment
  • Recommendations for corrective work

Who needs it

Who we work for

  • Developers and contractors before handover
  • Designers and site supervisors
  • Facility managers of offices, hotels and hospitals
  • Industry and power plants
  • Public institutions
  • Home and apartment owners
Measurement in a duct
Measurement in a duct
Measurement at a grille
Measurement at a grille
Noise measurement
Noise measurement
Air permeability
Air permeability

FAQ

Frequently asked questions

What does accreditation mean?

Accreditation is formal confirmation by the Accreditation Body of Serbia (ATS) that the laboratory meets ISO/IEC 17025:2017 and is competent for the tests in its scope. Our accreditation number is 01-008.

What is in the scope of accreditation?

Thermo-technical testing of water and air installations, heat exchangers, air permeability of apartments and buildings, heat transmission and thermography, plus physical testing of the working environment, noise, sound insulation and reverberation time. The full list of methods and standards is in the table on this page.

When do I need a report from an accredited laboratory?

Typically for building handover and the occupancy permit, when the client or supervisor needs proof of workmanship, for inspections, and in disputes about construction quality or noise.

Since when is the laboratory accredited?

Initial accreditation: 3 September 2001. The current scope is valid from 28 July 2025 and the accreditation is valid until 15 March 2027.

Where do you work?

Our office and laboratory are in New Belgrade; testing takes place on site at your building. Locations outside Belgrade by arrangement.

How do I request a quote?

Send us the type of building, location and the test you need, or call +381 11 318 4248.

Contact

Tell us what needs testing.