SRPS EN ISO 9972:2016 · accredited

Blower door test and air permeability.

We measure how airtight the building envelope is: a fan in the doorway creates a pressure difference and we measure how much air passes through window joints, service penetrations and cracks. The test is within our ATS scope of accreditation.

  • ATS 01-008accredited lab
  • ISO/IEC 17025:2017
  • since 2001accredited
Δp 50 Pa−50 Pan501.4 h⁻¹Blower doorfanAManometerBAirleaksCn50 resultD
  • ABlower door fan
  • BDigital manometer
  • CAir leak locations
  • Dn50 result
  1. 1Fan and membrane fitted in the doorway
  2. 2Pressure difference up to 50 Pa
  3. 3Air enters through joints and cracks
  4. 4n50 result and leak locations
Values shown are illustrative.

What we measure

Blower door test

01

Building air permeability

Air leakage rate at a pressure difference and the n50 air change rate, by fan pressurization.

02

Apartments and test zones

Testing of individual apartments and test zones, including the SRPS U.J5.100 method.

03

Leak locations

We locate where air gets in, with thermography where useful.

04

Testing before finishes

Testing before services and façades are closed lets you fix leaks while it is cheap.

Accreditation and standards

ATS 01-008 scope of accreditation

The tests on this page are covered by the scope of accreditation of our Testing and Measurement Laboratory. Reports carry the accreditation mark; methods and ranges are listed below.

Accreditation No.
ATS 01-008
Standard
ISO/IEC 17025:2017
Initial accreditation
3 Sep 2001
Valid until
15 Mar 2027
SubjectTestRangeReference document
Apartments and buildingsAir permeability testing of apartments—SRPS U.J5.100:1984 (withdrawn)
Air permeability of buildings – fan pressurization method50–39 000 m³/hSRPS EN ISO 9972:2016

Scope of accreditation (PDF)

Process

How it works

  1. Preparing the building

    Windows and external doors are closed; vents and flues are temporarily sealed.

  2. Fitting the fan

    The blower door frame with membrane and fan goes into the external doorway.

  3. Pressure series

    We depressurize and pressurize in steps up to 50 Pa and beyond and record the flow.

  4. Locating leaks

    Under depressurization we find where air enters.

  5. Calculation

    The air permeability and n50 are calculated from the flow–pressure curve.

  6. Report

    A test report with results and recommendations.

What you get

Report and results

  • Test report to EN ISO 9972:2016
  • Flow vs. pressure-difference curve
  • n50 air change rate and derived values
  • Test zone and building preparation
  • Leak locations and recommendations

Who needs it

Who we work for

  • Low-energy and passive house developers
  • Window and façade contractors
  • Energy efficiency designers
  • Buyers of new homes
  • Building managers planning energy retrofits
Blower door test on site
Blower door test on site
Airflow measurement
Airflow measurement

FAQ

Frequently asked questions

What is a blower door test?

It is an air-tightness test of the building envelope. A fan in the doorway creates a pressure difference and the air permeability is calculated from the measured flow. The method is described in EN ISO 9972:2016.

What does n50 mean?

n50 is the number of air changes per hour at a 50 Pa pressure difference. Lower is tighter.

Is the test accredited?

Yes. Building air permeability to SRPS EN ISO 9972:2016 (range 50–39,000 m³/h) and apartment air permeability to SRPS U.J5.100:1984 are in our ATS 01-008 scope.

When is the best time to test?

When the envelope is complete but interior linings are still open, so leaks are easy to fix. Finished buildings can be tested too.

How long does it take?

For a house or apartment usually a few hours on site, depending on preparation and the number of zones.

Do I need it for an energy passport?

The result can be used as input to the energy calculation; whether it is required depends on the project and the client.

Contact

Tell us what needs testing.

Send the building type, location and the test you need, and we will reply with a quote and a date.